What Is the Recommended R Value for Roof Insulation?

Not all of the insulation in the roof comes from the material that is laid or blown between the joists, and not all new homes that comply with local regulations have enough insulation.

The Basics

Even new home insulation may not meet recommended levels.Even new home insulation may not meet recommended levels.
Adding insulation to a new building design is fairly easy, but even adding insulation to older homes can pay for itself in energy savings. Fortunately, guidance is available for those who don't have an encyclopedic knowledge of building codes or enough facility with geometry to figure out how much insulation is needed in the attic.

The ability of a material to resist heat -- its "thermal resistance" -- is measured in units called R-values. Even wallboard and wallpaper insulate to a degree, but the best insulators trap air, much as multiple-pane windows do. New buildings have levels of insulation required by local building codes, and building materials can add values of R-5 or R-6 to roofs. Most roofs, however, need additional insulation to reach levels recommended by the Department of Energy (DOE).

Zones

Roofs protect interiors against summer heat and capture rising heat in winter.

The DOE divides the U.S. into eight zones and recommends insulation levels for each. Zone 1 includes only the southern tip of Florida; a total value of R-30 to R-49 keeps heat out of homes. In zone 8 portions of Alaska, where the recommended R-value in roof insulation is as high as R-60, the objective is to keep heat inside buildings. Building specifications only list R-values, not materials, says the Oregon Department of Energy. As a result, materials must be labeled as to the thickness of batt or the weight of loose fill material required to accomplish specific R-values.

Features

Insulating the attic floor conserves material and allows ventilation under the roof.

Batts and loose fill are laid between joists in attic spaces; "cathedralized" ceilings in attics or rooms can be insulated with spray or batts. A pitched roof requires more material to insulate because of its greater area and because gravity pulls insulation down toward the eaves, leaving less at the peak. In zones 2 and 3, covering most of the Deep South, the average depth of insulation should have an R-value of 30 to 60. In zone 4, which includes the mid-South and Northwest Pacific coastal areas, it should average 38 to 60.

Considerations

Fill antenna, repair and other openings before retrofitting an older roof.

Much batt insulation consists of wool or fiberglass; loose fill may be cellulose, fiberglass or polyethylene. Polyisocyanurate, polyurethane and extruded polystyrene foams work well for filling small openings or limited access spaces. R-value of existing insulation is figured by a simple calculation, depending on the material; 18.75 inches of fiberglass batt multiplied by 3.2 yields an R-value of 60. The same R-rating would require 24 inches of loose fill fiberglass. If 3 to 4 inches of roof insulation already exists, buildings would need materials adding up to the recommended levels. Zone 5, 6, 7 and 8, for example, could add a combination of batts or batts and loose fill that would total ratings of R-38 to R-49 to reach the recommended levels of R-39 to R-60.

About the Author

An avid perennial gardener and old house owner, Laura Reynolds has had careers in teaching and juvenile justice. A retired municipal judgem Reynolds holds a degree in communications from Northern Illinois University. Her six children and stepchildren served as subjects of editorials during her tenure as a local newspaper editor.